¼ò½é

ÔÚ¹ý³Ì×Ô¶¯»¯ºÍ½»Í¨×Ô¶¯»¯Ó¦ÓÃÖм¯ºÏÁ˸÷ÖÖÊÓƵ¡¢ÒôƵÊý ¾Ý£¬Òò´ËÐèÒª¸ßÐÔÄܺ͸߿ɿ¿ÐÔµÄÍøÂç»·¾³¡£ICS-G7826/ G7828ϵÁÐȫǧÕ׹Ǹɽ»»»»ú¾ß±¸24¸öǧÕ×ÒÔÌ«Íø¿Ú£¬ÒÔ¼° ¶à´ï4¸öÍòÕ×ÒÔÌ«Íø¿Ú£¬Ö§³Ö3²ã·Óɹ¦ÄÜ£¬Ê¹¿çÍøÂçµÄÓ¦Óà ²¿Êð¸ü¼òµ¥£¬·Ç³£Êʺϴó¹æÄ£¹¤ÒµÍøÂçµÄÓ¦Óá£ICS-G7826/ 24G+2 10GbE/24G+4 10GbE¿ÚȫǧÕ×Íø¹ÜÐÍÈý²ãÒÔ Ì«Íø½»»»»ú G7828ȫǧÕ×ͨѶ¹¦ÄÜÔö¼ÓÁË´ø¿í£¬Æä¸ßÐÔÄÜÈ·±£ÔÚÍøÂçÉÏ ¿ìËÙ´«Êä´óÁ¿µÄÊÓƵ¡¢ÒôƵºÍÊý¾ÝÐÅÏ¢¡£¸ÃϵÁн»»»»úÖ§³Ö Turbo Ring£¬Turbo ChainºÍRSTP/STPÈßÓàЭÒ飬ÎÞ·çÉÈÉè ¼Æ£¬¸ôÀëÈßÓàµçÔ´£¬ÔöÇ¿ÁËϵͳ¿É¿¿ÐԺ͹ǸÉÍøÂçµÄ¿ÉÓÃÐÔ¡£

ÓÅÊÆÓëÌصã

  • Èý²ã½»»»¹¦Äܽ«´óÐÍÍøÂç»®·Ö³É²»Í¬µÄ×ÓÍø£¬ÔÊÐíÊý¾ÝÐÅÏ¢ ÔÚÍøÂçÉϽøÐÐͨѶ
  • Ö§³ÖTurbo Ring£¬Turbo Chain£¬RSTP/STPºÍMSTPÍøÂçÈßÓà
  • IGMP SnoopingºÍGMRP¹ýÂË×é²¥·â°ü
  • Ö§³ÖIEEE 802.1Q VLANºÍGVRPЭÒ飬¼òÒ×ÍøÂç¹æ»®
  • Ö§³ÖQoS£¨IEEE802.1p/1Q£©ºÍTOS/DiffServ£¬Ôö¼ÓÍøÂçÎȶ¨ÐÔ
  • ²ÉÓÃIEEE 802.3ad£¬LACPÓÅ»¯ÍøÂç´ø¿í
  • Ö§³ÖIEEE 802.1X£¬HTTPSºÍSSH£¬¼ÓÇ¿ÍøÂ簲ȫÐÔ
  • Ö§³ÖSNMPv1/v2c/v3²»Í¬µÈ¼¶µÄÍøÂç¹ÜÀíЭÒé ¹æ¸ñ
  • ²ÉÓÃRMONÓÐЧÌáÉýÍøÂç¼à²âºÍÔ¤²âÄÜÁ¦
  • Ö§³Ö´ø¿í¹ÜÀí£¬È·±£ÍøÂçÎȶ¨ÐÔ
  • Ö§³Ö»ùÓÚMACµØÖ·µÄ¶Ë¿ÚËø¶¨£¬·ÀÖ¹·Ç·¨ÈëÇÖ
  • Ö§³Ö¶Ë¿Ú¾µÏñ¹¦ÄÜ£¬±ãÓÚÔÚÏßµ÷ÊÔ
  • ͨ¹ýE-mailºÍ¼ÌµçÆ÷Êä³ö×Ô¶¯±¨¸æÒâÍâʼþ
  • ×Ô¶¯»Ö¸´ÔÚÏßÉ豸µÄIPµØÖ·
  • ×Ô¶¯¿ìËÙÏß·»Ö¸´
  • ¿Éͨ¹ýÍøÒ³ä¯ÀÀÆ÷£¬Telnet/Serial consoleºÍ Windows utility ½øÐÐÅäÖÃ

¼¼Êõ²ÎÊý ±ê×¼£º
IEEE 802.3ÊÊÓÃÓÚ10BaseT
IEEE 802.3uÊÊÓÃÓÚ100BaseT£¨X£©and 100BaseFX
IEEE 802.3abÊÊÓÃÓÚ1000BaseT£¨X£©
IEEE 802.3zÊÊÓÃÓÚ1000BaseSX/LX/LHX/ZX
IEEE 802.3aeÊÊÓÃÓÚ10 Gigabit Ethernet
IEEE 802.3xÊÊÓÃÓÚFlow Control
IEEE 802.1DÊÊÓÃÓÚSpanning Tree Protocol
IEEE 802.1wÊÊÓÃÓÚRapid STP
IEEE 802.1QÊÊÓÃÓÚVLAN Tagging
IEEE 802.1pÊÊÓÃÓÚClass of Service
IEEE 802.1XÊÊÓÃÓÚAuthentication
IEEE 802.3adÊÊÓÃÓÚPort Trunk with LACP
ЭÒ飺IGMPv1/v2 device£¬GMRP£¬GVRP£¬SNMPv1/v2c/v3£¬
DHCP Server/Client£¬DHCP Option 82£¬BootP£¬TFTP£¬SNTP£¬
MsTP£¬RARP£¬RMON£¬HTTP£¬HTTPS£¬Telnet£¬SSH£¬Syslog
Èý²ã½»»»¼¼Êõ£º¾²Ì¬Â·ÓÉ£¬RIP V1/V2£¬OSPF£¬VRRPÖ§³Ö·ÓÉÆ÷
ÈßÓà
MIB£ºMIB-II£¬Ethernet-like MIB£¬P-BRIDGE MIB£¬
Q-BRIDGE MIB£¬Bridge MIB£¬RSTP MIB£¬RMON MIB
Groups 1£¬2£¬3£¬9
Á÷¿Ø£ºIEEE 802.3xÁ÷Á¿¿ØÖÆ£¬±³Ñ¹Ê½Á÷¿Ø
½»»»ÊôÐÔ ÓÅÏȼ¶£º8
×î¶à¿ÉÓõÄVLANÊý£º256
VLAN ID·¶Î§£ºVID 1 ~ 4094
IGMP×飺1000
MAC±í´óС£º16 K
·â°ü»º³åÇø´óС£º12 Mbit
½Ó¿Ú ǧÕ×ÒÔÌ«Íø¿Ú£º10/100/1000BaseT£¨X£©»ò
100/1000BaseSFP²å²Û
ÍòÕ×ÒÔÌ«Íø¿Ú£º10GbE SFP+²å²Û
¿ØÖÆ¿Ú£ºRS-232£¨RJ45½Ó¿Ú£©
LED ָʾµÆ£ºSTAT£¬PWR1£¬PWR2£¬FAULT£¬MSTR/HEAD£¬
CPLR/TAIL
±¨¾¯´¥µã£º1·¼ÌµçÆ÷Êä³ö£¬µçÁ÷¸ºÔØÄÜÁ¦ 2 A @ 30 VDC
Êý×ÖÊäÈ룺1·Êý×ÖÊäÈ룬µçÆø¸ôÀ룬¹²µØ
• ״̬¡°1¡±£º+13 ~ +30V
• ״̬¡°0¡±£º-30 ~ +3V
• ×î´óÊäÈëµçÁ÷£º8 mA
µçÔ´ÐèÇó ÊäÈëµçѹ£º110/220 VAC£¨85 ~ 264 VAC£©
ÊäÈëµçÁ÷£º
ICS-G7826£ºMax.0.98/0.55 A @ 110/220 VAC
ICS-G7828£ºMax.1.16/0.65 A @ 110/220 VAC
¹ýÁ÷±£»¤£ºÌṩ
·´½Ó±£»¤£ºÌṩ
»úеÌØÐÔ Íâ¿Ç£ºIP30·À»¤µÈ¼¶
³ß´ç£º440 x 44 x 386.9 mm£¨17.32 x 1.73 x 15.23 in£©
°²×°£º19¡±»ú¼Üʽ°²×°
¹¤×÷»·¾³ ¹¤×÷ζȣº0 ~ 60 ¡ãC£¨32~140 ¡ãF£©
´æ´¢Î¶ȣº-40 ~ 85 ¡ãC£¨-40~ 185 ¡ãF£©
Ïà¶Ôʪ¶È£º5 ~ 95%£¨ÎÞÄý¶£©
°²¹æÈÏÖ¤ Safety£ºUL 60950-1£¨ÈÏÖ¤ÖУ©£¬EN 60950-1£¨ÈÏÖ¤ÖУ©
EMI£ºFCC Part 15 Subpart B Class A£¬EN 55022 Class A
Rail Traffi c£ºEN 50121-4
×¢£ºÇëµÇ½MoxaÍøÕ¾£¬»ñÈ¡×îÐÂÈÏÖ¤ÐÅÏ¢¡£
±£ÐÞ ±£ÐÞÆÚ£º5Äê

 


¹«Ë¾¼ò½é
²úƷĿ¼
¹©Ó¦ÐÅÏ¢

¹«Ë¾Ãû³Æ£º Ħɯ¹ú¼ÊóÒ×£¨ÉϺ££©ÓÐÏÞ¹«Ë¾
µç »°£º 021 52589955 / Íõ С ½ã
ÊÖ»ú£º
µØ Ö·£º ÉϺ£ÊÐÑÓ°²Î÷·1160ºÅÊ×ÐÅÒø¶¼¹ú¼Ê¹ã³¡18²ã
ÓÊ ±à£º 200052
Ö÷ Ò³£º http://www.moxa.com.cn

¸Ã³§ÉÌÏà¹Ø²úÆ·£º
  • moxa EDR-810ϵÁÐ
  •  
  • moxa MD-119ϵÁÐ º£ÊÂרÓÃÏÔʾÆ÷
  •  
  • moxa MXview2.3ÍøÂç¹ÜÀíÈí¼þ
  •  
  • moxa ioLogik R1241
  •  
  • ioLogik R1240
  •  
  • moxa ioLogik R1214
  •  
  • moxa ioLogik R1212
  •  
  • moxa ioLogik R1210
  •  
  • moxa IEX-402-VDSL2ϵÁÐ
  •  
  • moxa MGate™ 5102-PBM-PNϵÁÐ
  •  
    ¸ü¶à²úÆ·...
      ¹ØÓÚÎÒÃÇ | ÁªÏµÎÒÃÇ | ¹ã¸æ·þÎñ | ±¾Õ¾¶¯Ì¬ | ÓÑÇéÁ´½Ó | ·¨ÂÉÉùÃ÷ | ·Ç·¨ºÍ²»Á¼ÐÅÏ¢¾Ù±¨  
    ¹¤¿ØÍø¿Í·þÈÈÏߣº0755-86369299
    °æȨËùÓÐ ¹¤¿ØÍø Copyright@ Gkong.com, All Rights Reserved